Tech Tips - Jan 18

This code is a common code on an ES Scissor, most frequently generated by a battery connection issue or battery replacement.

However, there is an easy fix:
  • Simply go in with your analyzer under access level 1, change your model number to a different model and then shut the machine down with the e-stop switch
  • Power the machine back up and go in with your analyzer under access level 1 again and change the model back to the correct number
  • Shut the machine down with the e-stop switch and that should eliminate the code